Department of Chemistry and Chemical Biology

AMBER BUGS -- NOT FIXED


Some bugs are known and not fixed, and may never be fixed for a variety of reasons. If you fix one, please let us know at amber-request@cgl.ucsf.edu so we can test and install your fix as well as announce it (with full attribution!) on the amber reflector.
  • The "deviations from ideal bond lengths and angles" reported in NMR refinements in MPI versions of sander are not correct. Run a final step on a single-processor to get the correct values.

  • Resp does not work when compiled on R4400 machines under IRIX 6.2; other SGI configurations may also fail. Has to do with the namelist implementation; current work-around is to use a different machine(!)

  • The automated tests of Link, Edit, and Parm fail on DEC alpha machines, because of byte-ordering problems. This is a problem with the test suite, *not* with the programs themselves, which we believe are fine.

  • LINK does not generate dihedrals about a covalent bond generated with the ICONN=1 option with specification of NA0/NM0. Defining the bond as a crosslink with ICROSL=1 works ok.

  • EDIT places sugar hydrogens wrong for A DNA. One solution is to fix the coordinates by hand and load the correct coordinates in the PDB file. Or use leap, which places hydrogens correctly.

  • In the test suite, ANAL gives one wrong measurement on Crays for nucleic acid sugar pucker phase:
            73c73
            <       5   10 - CYT         0.39     61.23
            ---
            >       5   10 - CYT         0.39    118.77
    
  • ANAL energy discrepancy